Section 74A of the Road Safety Act 1986 (Vic) prohibits the sale of breath analysing instruments that do not conform to Australian Standard AS 3547. The offence carries a maximum fine of 20 penalty units ($4,182 at the 2026–27 rate). There is no imprisonment, and no mandatory licence disqualification. Whether a particular device is captured depends on whether it falls within the Standard's scope and whether it meets the prescribed technical requirements.
Charged under s 74A? Call 1300 331 331 for a free consultation with a Victorian criminal defence lawyer.
Breath analysing instruments sold to the public range from pocket-sized personal-use devices to more elaborate units marketed as "professional" testers. The concern Parliament addressed in s 74A is that a device which does not meet technical accuracy standards could give a driver false confidence that they are under the legal limit. A driver who relies on a non-compliant device and drives believing they are safe may in fact be over the limit.
The mechanism for ensuring accuracy is Australian Standard AS 3547, published by Standards Australia, which sets out technical and performance requirements for breath alcohol measuring instruments. Section 74A makes it an offence to sell any instrument of a class or type covered by AS 3547 unless the specific device complies with that standard.
Section 74A of the Road Safety Act 1986 (Vic) provides that a person must not sell a breath analysing instrument of a class or type to which Australian Standard AS 3547 applies, unless the instrument complies with that standard.
| Element | Detail |
|---|---|
| Legislation | s 74A Road Safety Act 1986 (Vic) |
| Court | Magistrates' Court of Victoria |
| Maximum penalty | 20 penalty units ($4,182 at the 2026–27 rate) |
| Imprisonment | None |
| Licence disqualification | None |
| Penalty unit value (2026–27) | $209.10 per unit |
The prosecution must establish beyond reasonable doubt that:
The central question in most matters is the second element: whether the device sold falls within the scope of AS 3547. If it does not, the section does not apply regardless of whether the device was accurate or inaccurate.
AS 3547 (Breath alcohol testing devices), current edition 2019, sets performance requirements for instruments used to estimate blood alcohol content from a breath sample. Section 74A references the Standard as amended from time to time, so it applies to the current edition. AS 3547:2019 defines three types of instrument:
| Type | Description |
|---|---|
| Type 2 | Portable electronic device intended for personal, non-evidential use. |
| Type 3 | Electronic device for fixed-site installation, designed for professional or semi-professional use in a controlled environment. |
| Type 4 | Alcohol interlock device designed to prevent a vehicle from starting if the driver's breath alcohol exceeds a set threshold. |
Single-use disposable devices (formerly Type 1 under the superseded 1997 edition) were removed from AS 3547 when the standard was revised in 2019 and are no longer within its scope.
Evidential breath analysers used by Victoria Police, such as the Alcotest 7110 and the Alcotest 9510 AUS, are not within the scope of AS 3547 in the consumer sense. Those instruments are approved under the National Measurement Institute (NMI) pattern approval system under the National Measurement Act 1960 (Cth). The Alcotest 7110 holds NMI approval NMI 16/1/2. That is a separate approval framework from AS 3547 and from the Road Safety Act's consumer instrument regime. A seller of those devices to a private buyer would not fall under s 74A, though other provisions could apply.
A "sale" in its ordinary legal sense requires a contract under which property in goods is transferred from seller to buyer in exchange for a money price. Giving away a device, lending it, or demonstrating it without any transfer of ownership is not a sale. A sale at a discounted price is still a sale. An online listing that results in a completed purchase in Victoria can constitute a sale in Victoria even if the seller is located elsewhere.
Whether a particular device complies with the Standard is a technical question. Compliance requires that the device meets the performance specifications in AS 3547 for its type, including accuracy thresholds at various concentrations, repeatability requirements, and requirements relating to interference rejection. A device that was compliant when manufactured but has since degraded beyond specification due to wear, contamination, or calibration drift may no longer comply, but whether a seller could be liable for that depends on whether the non-compliance was present at the time of sale and whether the seller knew or ought reasonably to have known of it.
If the device sold is not a breath analysing instrument of a class or type to which AS 3547 applies, the section is not engaged. This is the most commonly available defence for sellers of novelty or display items marketed to appear like breath testers but which operate on entirely different principles or are not calibrated to measure breath alcohol at all.
Compliance with the Standard is a complete answer to the charge. If the device was compliant at the time of sale, no offence is committed. A seller who can produce documentation of compliance, such as a manufacturer's certification, test reports, or evidence of an accredited conformity assessment, may be able to establish this in response to the charge.
Section 74A does not expressly state a fault element. Where a provision does not specify a fault element, the common law defence of honest and reasonable mistake of fact may be available. A seller who honestly and reasonably believed a device was compliant, on the basis of representations from the manufacturer or distributor, may be able to rely on this defence. The belief must have been both honest (actually held) and reasonable (with a proper basis).
If the transfer of the device was a gift, a loan, a demonstration, or otherwise not a sale for consideration, the section is not satisfied.